Installation and debugging steps For Shaking Table
Shaking table motor through the belt drive to shake the crankshaft of the bed equipment crank rocker followed by up and down motion, rocker downward motion, in the inclined table with a sheet ore material through the mine trough in, shaker trough to provide transverse impact water, such a side of vibration, While washing, specific gravity and particle size, density of different minerals along different directions from the bed surface of the shaker fine ore mouth, and tailings mouth outflow, directly forming high quality concentrate.

Cement and anchor bolts should be embedded before shaker installation. During installation, attention should be paid to the fact that the center of the circle with the radius of the two slope regulator seat of 360 mm and the center of the bed linkage seat are in the same plane. Otherwise, when the bed is tilted, it will accelerate the wear of the copper sleeve and even break the reciprocating rod. As for the traction screw height error between the linkage seat and the bed surface, the bolts under the shaking box can be adjusted to eliminate it.

The shaking table has been made free charge debugging operation when leaving the factory, the user should first make two small time and space charge debugging operation after the equipment is installed, and check the following items: starting operation process of the motor is normal; Contact condition of each part and wear condition of friction joint surface; Whether there is abnormal noise; Whether the lubrication is normal. Then the load test can be carried out. Check the above items after 24 hours.

The test run time and load running spring should not be too tight, should be slightly relaxed, so that the running elbow plate and its support for a slight impact of the sound, at this time should gradually adjust the bolt, the spring pressed to stop the sound. Excessive compression spring will increase wear and power consumption, and may be broken spring, spring pressure too loose easy to cause toggle off accident, damage the box parts.