Product introduction

Electrothermal Blowing drying oven is designed specially for drying of material which is thermo-sensitive or decompounded and oxidative easily, it can be filled with inert gases, which is especially for a rapid drying of some compound material, widely applied in pharmaceuticals, electronics industry and chemical industry.

The series of resistance furnace is a batch type, for laboratory, industrial and mining enterprises, scientific research units for elemental analysis of heat treatment determination and general small steel parts quenching, annealing, tempering heating. The rated temperature box type resistance furnace at a temperature of 300 DEG C, can be used as alloy steel heat treatment and metal melting, high temperature heating analysis etc. It is a kind of ideal has broad prospects drying equipment, such as

Laboratory to try drying, heat treatment, baking, melting wax, sterilization and heating, but do not apply to the volatile,flammable and explosive items, lest cause explosion.

 
未标题-10
未标题-9
未标题-8

Product application

Method of use 

1. Put the items to be dried into the drying oven and close the door. 

2. Turn the power switch to 1. The power switch is on and the digital display is displayed. 

3. Set the required working temperature and working time according to the operation instructions of the temperature controller (the working time is optional). 

4. The device will automatically run under the required working conditions. After use, turn off the power switch and take out the items. 

※ If the operating temperature is too high (generally higher than 70℃), please wait until the equipment is cooled before taking out the goods 

Instructions for using the temperature controller 

1. Set the temperature 

a. Under normal working condition, press the SET key to enter the temperature setting state. At this time, the PV display displays SP, and the first part of the SV display flashes; 

b. Press the shift key to move the flicker to the desired setting; 

c. Press the Minus key or the plus key to adjust the number to the desired value; 

d. Press the SET key twice, the instrument will return to the normal working state, the temperature setting is completed, and the instrument will run according to the new set value. 

2. Timing function 

a. Under normal working condition, press the SET key twice to enter the timing setting state. At this time, PV display displays ST, SV display displays 0, and flashes; 

b. Press the shift key to move the flicker to the desired setting; 

c. Press the Minus key or the plus key to adjust the number to the desired value; 

d. Press the SET key, the instrument will enter the timed running state, and the running indicator will blink; 

e. Timing function is countdown operation. Under timing operation condition, press the shift key, and the SV display screen will display the remaining time of timing; 

f. The remaining time of timing returns to zero, and the instrument enters the timed End state. At this time, the SV display displays END and flashes, and all indicators except the wind speed indicator are off;

 

Equipment model

Model
Voltage
V
Heater KW
temperature ℃
Work size mm
Weight
KG
 
 
 
 
L
W
H
 
LZ101-1
220
2.5
50~300
350
450
450
70
LZ101-2
220
3.2
50~300
450
550
550
100
LZ101-3
220
6
50~300
500
600
750
140
LZ101-4
3X380
9
50~300
800
800
1000
350
LZ202-0
220
1.2
50~300
250
250
250
40
LZ202-00
220
2
50~300
350
350
350
50
LZ202-1
220
2.5
50~300
350
450
450
60
LZ202-2
220
3.2
50~300
450
550
550
80
LZ202-3
220
6
50~300
500
600
750
130
LZ202-4
3X380
9
50~300
800
800
1000
330